Viešosios greito įkrovimo stotelės Maxi EU DC W60 S
- Sandėlyje: Klauskite
- Prekės kodas: Viešosios greito įkrovimo stotelės MaxiEUDCW60 S
Part Numbers
DCFC 60KW-120KW:
60kW: UF060xxxxx; 80kW: UF080xxxxx;
100kW: UF100xxxxx; 120kW: UF120xxxxx
DCFC 140KW-240KW:
140kW: UF140xxxxx; 160kW: UF160xxxxx;
180kW: UF180xxxxx; 200kW: UF200xxxxx;
220kW: UF220xxxxx; 240kW: UF240xxxxx
The "xxxxx" portion of the product part number represents the various product configurations.
Electrical
Connector Option*
DCFC 60KW-120KW:
60kW: UF060xxxxx; 80kW: UF080xxxxx;
DCFC 140KW-240KW:
Dual CCS1/CCS1 Boost, or CCS1 + CHAdeMO
Max. Input AC Current
DCFC 60KW-120KW:
60kW: 91A; 80kW: 122A;
100kW: 152A; 120kW: 182A
DCFC 140KW-240KW:
140kW: 213A; 160kW: 245A; 180kW: 270A;
200kW: 305A; 220kW: 335A; 240kW: 365A
Nominal Input AC Current
DCFC 60KW-120KW:
60kW: 83A; 80kW: 110A;
100kW: 138A; 120kW: 165A
DCFC 140KW-240KW:
140kW: 181A; 160kW: 207A; 180kW: 230A;
200kW: 260A; 220kW: 285A; 240kW: 310A
Input Voltage Range
480 V AC - 15 % to +10 % @ 60 Hz
DC Output Voltage
CCS1: 150 to 950 V DC; CHAdeMO: 150 to 500 V DC
Network Type
TN-S, TN-C, TN-C-S, & TT (External RCD** Required)
AC Input Connection
3P + PE (No Neutral)
Protection
Over-Current, Over-Voltage, Under-Voltage, Ground-Fault, Over-Temperature, Short-Circuit, Insulation Monitor (IMD), & Surge Protection
Overvoltage Category
AC Side (Input) OVC: III
Power Factor (>50% Load)
≥ 0.98
THDI (>50% Load)
≤ 5 %
Peak Efficiency
≥ 96 %
Standby Power
80 W
Short Circuit Current Rating
≥ 65 kA
Energy Metering
Class A
User Interface & Communication
Connectivity
Internet Access Via 4G / Wi-Fi / Ethernet (RJ 45)
User Authentication
QR Code, RFID, Credit Card (Optional)
ISO 15118 Plug & Charge
Yes
DIN 70121
Yes
Interface
27” LCD High-Contrast Touchscreen (15.6” Optional)
Accessible For Wheel Chair Users
Yes
Communications Protocols
OCPP 1.6 JSON, OCPP 2.0.1 (Can Be Upgraded Later)
RFID Reader
ISO 14443 A+B to Part 4 & ISO/IEC 15693, Mifare, NFC, Calypso, Ultralight, PayPass, HID & More
Emergency Button
Yes
Software Update
OTA Update Via Web Portal
Control And Configuration
Web Portal, On-Board Service Portal
General Characteristics
Protection Ratings
NEMA 3R Outdoor Use & IK-10
Enclosure Type
Stainless Steel 430
Operation Altitude
6561 Ft. (6561 to 9843 Ft. with Power Derating)
Operation Temperature
-31 °F to +131 °F (+122 °F to +131 °F with Linear Power Derating)
Storage Temperature
-40 °F to +158 °F
Noise Level
< 65 dB @1 m/25 °/Full Load/800 VDC
Mounting
Free-Standing Cabinet
Cable Length
15 ft (Optional: 20 or 25 ft)
Dimentions (H X W X D)
DCFC 60KW-120KW:
76.8" x 32.3" x 23.6" (1950 x 820 x 600mm
DCFC 140KW-240KW:
76.8"x 32.3"x 27.6" (1950 x 820 x 700 mm)
Certification and Standards
Safety and Compliance
UL 2202, UL 2231-1, UL 2231-2, NEC Article 625, CSA C22.2 No. 107.1-16
EMC compliance
FCC Part 15 Class A, Class B (Optional)
Warranty
24 months, warranty extension possible